Buying guides · Capacitors

Check electrolytic capacitor ripple current before an RFQ

By VEQORIN · Published

Two aluminum electrolytic capacitors can have the same capacitance, voltage rating and case size while carrying different ripple-current ratings. If the capacitor sits in a power supply or another circuit with substantial AC current, send more than those three headline values with the RFQ. The design owner needs to compare the actual current and temperature with the proposed part's datasheet conditions.

Read the number with its conditions

The ripple-current rating is an RMS current under stated conditions, not a current that can be applied at any frequency and temperature. Check the frequency and temperature printed beside the rating, then the correction factors for that specific series. Panasonic's aluminum electrolytic catalog, for example, publishes frequency correction tables and sometimes gives separate ripple-current figures at 120 Hz and 100 kHz. A figure copied from one column without its test conditions is easy to misuse.

If the circuit has both low-frequency and switching-frequency components, do not compare the sum of their peak values with a single catalog number. Ask the design team for the measured or calculated current waveform, its RMS components and the applicable series guidance. Nichicon's technical notes explain that equivalent series resistance varies with frequency and that mixed-frequency ripple must be assessed against the relevant coefficients. The calculation and thermal check belong to the design owner; an RFQ alone does not validate the circuit.

Keep temperature and lifetime separate

Ripple current causes internal heating. Nichicon describes the effect on an aluminum electrolytic capacitor's life through the resulting temperature rise. Ambient temperature is therefore only part of the operating temperature; heat from nearby parts and the capacitor's own losses also matter. A catalog endurance figure is a specified test condition, not a guaranteed lifetime in the customer's equipment.

Check the proposed device's rated voltage, maximum operating temperature, endurance conditions, polarity, dimensions and mounting method alongside ripple current. Panasonic's application guidelines warn that excessive ripple current can increase internal heat and shorten life. They also say the peak applied voltage, including the superimposed ripple, must not exceed the rated voltage; polarity and the series' other limits still apply. Keep these circuit requirements in the request rather than approving an alternative from headline ratings alone.

What to send with the enquiry

ItemUseful detail
Approved partFull manufacturer ordering code, series, quantity and required packaging
Circuit conditionsDC voltage, ripple waveform or RMS components, relevant frequencies, temperature near the capacitor and estimated capacitor temperature if known
Mechanical fitCase diameter and height, lead spacing or footprint, polarity and mounting method
ComparisonProposed part's datasheet revision, ripple rating with its frequency/temperature basis, applicable correction factors and endurance conditions
Open questionsAny missing waveform, thermal or lifetime requirement for the design owner to resolve

If those operating conditions are unknown, mark them as unknown rather than selecting a replacement from capacitance and voltage alone. The complete MPN guide and RFQ worksheet can help keep the request tied to the right part.

Sources and limits